4.1 The eleven designations and where each truck may go

The two or three letters on your data plate — E, GS, LPS, EX — are not a model code. They are a fire-safety classification, and they decide which parts of a building your truck may legally enter. 1910.178(b) lists eleven designations, and 1910.178(c) says where each one may and may not go. It is the part of the standard operators are least often taught and most likely to breach without knowing.

1 Eleven designations

1910.178(b) is explicit: for the purpose of the standard there are eleven different designations of industrial trucks or tractors — D, DS, DY, E, ES, EE, EX, G, GS, LP and LPS. Read as a family, the pattern is easy: the base letter is the power source, and additional letters mean additional safeguards.

29 CFR 1910.178(b) — the eleven designations
CodePowerWhat the extra letters mean
GGasolineMinimum acceptable safeguards against inherent fire hazards
GSGasolineAdditional safeguards to the exhaust, fuel and electrical systems
DDieselSimilar to G, diesel powered
DSDieselAdditional safeguards to the exhaust, fuel and electrical systems
DYDieselAll the safeguards of DS, plus no electrical equipment at all including ignition, plus temperature limitation features
LPLiquefied petroleum gasSimilar to G, LP fueled
LPSLiquefied petroleum gasAdditional safeguards to the exhaust, fuel and electrical systems
EElectricMinimum acceptable safeguards against inherent fire hazards
ESElectricAdditional electrical safeguards to prevent hazardous sparks and limit surface temperatures
EEElectricAll of E and ES, plus motors and all other electrical equipment completely enclosed
EXElectricElectrical fittings and equipment designed so the unit may be used in certain atmospheres containing flammable vapors or dusts

EX is the outlier and the one worth remembering by name: it is the only designation the standard allows in several atmospheres where every other truck is prohibited.

2 Classify the location first

1910.178(b)(12) sets the order of operations, and it is the opposite of how most sites think about it: the atmosphere or location shall have been classified as to whether it is hazardous or nonhazardous prior to the consideration of industrial trucks being used there, and the type of truck required shall be as provided in the standard for that location.

In other words, nobody starts from the truck. Somebody classifies the room, and the classification produces the list of trucks allowed in it. That classification is your employer's responsibility, and 1910.178(l)(3)(ii)(F) makes hazardous (classified) locations where the vehicle will be operated a required training topic — which means you are entitled to be told which areas on your site are classified and what may enter them.

Common mistake: assuming an electric truck is automatically safe in a flammable atmosphere. A plain E unit has motors, contactors and a battery that can spark. That is exactly why ES, EE and EX exist as separate designations.

3 Where no truck may go

1910.178(c)(2)(i) contains an absolute prohibition, and it is worth reading as written. Power-operated industrial trucks shall not be used in atmospheres containing hazardous concentrations of acetylene, butadiene, ethylene oxide, hydrogen — or gases or vapors equivalent in hazard to hydrogen, such as manufactured gas — propylene oxide, acetaldehyde, cyclopropane, diethyl ether, ethylene, isoprene, or unsymmetrical dimethyl hydrazine.

No designation is excepted there. Not EX, not DY. If a hazardous concentration of any of those is present, the answer is that the truck stays out.

1910.178(c)(2)(ii) then handles dusts: trucks shall not be used in atmospheres containing hazardous concentrations of metal dust — including aluminum, magnesium and their commercial alloys, and other metals of similarly hazardous characteristics — or in atmospheres containing carbon black, coal or coke dust, except approved trucks designated as EX. And 1910.178(c)(2)(iii) provides that only approved trucks designated EX may be used in atmospheres containing acetone, acrylonitrile, alcohol, ammonia, benzine, benzol, butane, ethylene dichloride, gasoline, hexane, lacquer solvent vapors, naphtha, natural gas, propane and similar vapors.

On the job: the practical version of this section is one question with one right answer. "Is this area classified, and is this truck's designation on the list for it?" If nobody on shift can answer, that is the finding, not the truck.

4 Choosing between power types

Outside classified locations, the choice between electric, LP, diesel and gasoline is driven by ventilation, duty cycle and the surface. The safety consequences are what matter here.

Practical trade-offs by power source
PowerStrengthHazard to manage
ElectricNo engine exhaust, quiet, good indoorsBattery hydrogen and acid; charging area rules — Chapter 2
LP gasRuns indoors with adequate ventilation, fast cylinder changeCarbon monoxide, cylinder handling, leaks — Chapter 3
DieselPower and duty cycle for yards and rough terrainExhaust in enclosed areas, fuel handling
GasolineAvailabilityFuel volatility, carbon monoxide, refueling fire risk

One conversion rule sits here rather than in the fuel chapter. 1910.178(q)(12) allows industrial trucks originally approved for the use of gasoline to be converted to liquefied petroleum gas fuel, provided the complete conversion results in a truck that embodies the features specified for LP or LPS designated trucks — and requires that the conversion equipment be approved. A conversion is not a bolt-on decision made in the shop.

5 Ventilation, temperature and the truck's own condition

Two housekeeping paragraphs in (q) belong to this chapter because they are about ignition sources on the truck itself. 1910.178(q)(9): when the temperature of any part of any truck is found to be in excess of its normal operating temperature, creating a hazardous condition, the vehicle shall be removed from service and not returned until the cause has been eliminated or corrected. 1910.178(q)(10): industrial trucks shall be kept in a clean condition, free of lint, excess oil and grease, and noncombustible agents should be used for cleaning.

1910.178(q)(8) adds a rule specific to engine trucks with water mufflers: they shall be filled daily, or as often as necessary to keep the water above 75 percent of filled capacity, and any vehicle that emits hazardous sparks or flames from the exhaust system shall immediately be removed from service and not returned until the cause has been eliminated.

The theme across all three is that a truck's fire-safety designation describes the machine as designed and maintained. A GS unit caked in lint with a hot exhaust is no longer the machine that was approved.

6 What to do when you are not sure

This is the one chapter of the course where the correct operator response to uncertainty is not "be careful" but "stop and ask." Classification is a documented determination made by your employer, not something an operator can infer from a smell or a sign on a door.

  1. 1
    Know your truck's designation. It is on the data plate. Photograph it, as Part 1 suggested.
  2. 2
    Know which areas on your site are classified, and what may enter each. This is required training content under (l)(3)(ii)(F).
  3. 3
    Treat an unclassified answer as a stop. 1910.178(b)(12) requires classification before the truck is even considered.
  4. 4
    Report changes. A new process, a new chemical or a new storage area can change a classification, and (l)(4)(ii)(E) makes a change in workplace conditions a refresher training trigger.
Key takeaways
  • 1910.178(b) defines eleven designations — D, DS, DY, E, ES, EE, EX, G, GS, LP, LPS — where extra letters mean extra safeguards.
  • 1910.178(b)(12): the location is classified first; the classification decides which trucks may be used there.
  • 1910.178(c)(2)(i) prohibits every powered industrial truck in hazardous concentrations of acetylene, hydrogen, ethylene oxide and the other listed gases — no designation is excepted.
  • Only EX trucks may be used in the metal, carbon black, coal and coke dust atmospheres of (c)(2)(ii) and the flammable vapor atmospheres of (c)(2)(iii).
  • An electric truck is not automatically safe in a flammable atmosphere — that is why ES, EE and EX exist.
  • (q)(9) and (q)(10): overheating removes a truck from service, and trucks must be kept free of lint, excess oil and grease.