5.1 Exit routes: how many, how wide, how marked
Exit routes are the one safety system in a warehouse that is judged entirely on a day nobody plans for, and the only one that gets quietly disabled by doing your job well. Nothing blocks an exit faster than a successful receiving shift. Subpart E of part 1910 is short, specific and worth reading in full — it is one of the few places OSHA gives you inches and feet.
1 The three words the standard uses
Subpart E splits an exit route into three parts, and the vocabulary matters because the requirements attach to different parts. The exit access is the portion that leads to an exit. The exit is the portion, generally separated by fire-resistant construction, that provides a protected way of travel. The exit discharge is the part that leads directly outside or to a street, walkway, refuge area, public way or open space with access to the outside — 1910.36(c)(1).
A warehouse's exit access is the aisle. That is why Part 1's aisle rules and this chapter are the same subject seen twice: the pallet in the aisle is a materials handling problem at 8 a.m. and an egress problem at any moment after that.
2 How many, how big
| Paragraph | Requirement |
|---|---|
| (b)(1) | At least two exit routes must be available, located as far apart as practical so that if one is blocked by fire or smoke, employees can use the other. |
| (b)(2)-(3) | More than two where the number of employees, the size, occupancy or arrangement of the workplace requires it; a single exit route only where everyone could evacuate safely with one. |
| (d)(1) | Employees must be able to open an exit route door from the inside at all times without keys, tools or special knowledge. A panic bar that locks only from the outside is permitted on exit discharge doors. |
| (d)(2) | Exit route doors must be free of any device or alarm that could restrict emergency use if the device or alarm fails. |
| (e)(2) | A door connecting a room to an exit route must swing out in the direction of travel if the room is designed for more than 50 people or is a high hazard area. |
| (g)(1) | Ceiling height at least 7 feet 6 inches; projections no lower than 6 feet 8 inches from the floor. |
| (g)(2) | An exit access must be at least 28 inches wide at all points. |
| (g)(4) | Objects that project into the exit route must not reduce its width below the minimum. |
| (f)(2) | The capacity of an exit route may not decrease in the direction of travel to the exit discharge. |
Two of those get violated routinely in warehouses. (d)(1) is broken by security: a door chained, bolted or fitted with a keyed lock at night because of theft. And (g)(2) and (g)(4) are broken by storage: a 44-inch corridor with pallets down one side is not a 44-inch exit access any more.
3 Free and unobstructed, in writing
1910.37(a)(3) is the paragraph to quote when somebody stages product in a corridor: "Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route." Temporarily is in the text. There is no ten-minute allowance and no "we're moving it after this trailer."
The same section adds three more: (a)(1) exit routes kept free of explosive or highly flammable furnishings or decorations; (a)(2) routes arranged so employees do not have to travel toward a high hazard area unless effectively shielded from it; and (a)(4) safeguards designed to protect employees during an emergency — sprinkler systems, alarm systems, fire doors, exit lighting — kept in proper working order at all times.
Fire doors deserve a note of their own, because propping them is so common. A fire door wedged open is a safeguard that is not in working order under (a)(4), and 1910.36(a)(3) requires openings into an exit to be protected by a self-closing fire door that remains closed or closes automatically on the alarm.
4 Lighting, marking and the signs nobody checks
1910.37(b) is unusually specific, and it is the easiest thing in this chapter to audit with a walk and a ladder.
- (b)(1) — each exit route adequately lighted so an employee with normal vision can see along it.
- (b)(2) — each exit clearly visible and marked by a sign reading "Exit."
- (b)(4) — where the direction of travel is not immediately apparent, directional signs along the exit access; the line of sight to an exit sign must be clearly visible at all times.
- (b)(5) — each doorway or passage that could be mistaken for an exit marked "Not an Exit" or identified by its actual use.
- (b)(6) — each exit sign illuminated to a surface value of at least five foot-candles by a reliable light source, and distinctive in color; self-luminous or electroluminescent signs need a minimum luminance of 0.06 footlamberts.
- (b)(7) — the word "Exit" in plainly legible letters not less than 6 inches high, with principal strokes not less than 3/4 inch wide.
5 Travel distance, occupant load and where OSHA stops
Two questions come up in every warehouse discussion and OSHA does not answer either one numerically. How far may someone have to travel to reach an exit, and how many exits does an occupant load require? Subpart E points elsewhere for both: the notes to 1910.36(b) and (f) refer the reader to NFPA 101, the Life Safety Code, and the International Fire Code, incorporated by reference at 1910.6.
Those are paid consensus documents; this course names them and does not reproduce their tables. What it means practically is that your building's exit count, travel distances and occupant load came from the building code and the fire marshal, not from OSHA — and that a change in use (adding a mezzanine, converting an area to high-piled storage, building a pick module) can invalidate the original design. That is a conversation with the fire marshal, not something to work out from part 1910.
6 During construction and alterations
Warehouses expand while they operate, and 1910.37(d) covers exactly that. During new construction employees must not occupy a workplace until the required exit routes are complete and ready for use for the portion they occupy. During repairs or alterations, employees must not occupy the workplace unless the required exit routes are available and existing fire protections are maintained — or alternate protection providing an equivalent level of safety is furnished.
And 1910.37(d)(3): employees must not be exposed to hazards of flammable or explosive substances or equipment used during the work that go beyond normal permissible conditions, or that would impede exiting. A contractor's spray-applied fireproofing or a temporary hoarding across a corridor is squarely in that paragraph. The practical control is a written interim life safety plan for the duration of the project — temporary exit signage, alternate routes walked with the crews, and a daily check that the temporary route is still clear.
- 1910.36(b)(1): at least two exit routes, located as far apart as practical; more where size or occupancy requires.
- 1910.36(d)(1): exit doors openable from the inside at all times without keys, tools or special knowledge.
- Exit access at least 28 inches wide, ceiling 7 ft 6 in, projections no lower than 6 ft 8 in; capacity must not decrease toward the discharge.
- 1910.37(a)(3): no materials or equipment in an exit route, permanently or temporarily.
- Exit signs: 6-inch letters, 3/4-inch strokes, at least five foot-candles, and the line of sight kept clear.
- Travel distance and occupant load come from NFPA 101 and the fire code, not from part 1910.
Free educational content — not OSHA-authorized training, no certificate or card issued. Follow your employer's program and the standards cited.