Emergency Action Plan Builder
29 CFR 1910.38(c) lists six things an emergency action plan must contain. This builder turns them into the six sections of a written plan you can print, post and review with the crew — plus the alarm, training and review paragraphs that come with them. It asks for your procedures; it never invents them. Nothing you type is sent to our servers.
Nothing you type is sent to our servers. A draft is kept in this browser until you clear it.
Template for informational purposes only. This document must be reviewed and adapted by a competent or qualified person for your specific jobsite, equipment, and applicable federal, state, and local requirements. It does not constitute legal, engineering, or safety advice and does not by itself establish compliance with OSHA or any other standard. SteelToeTools assumes no liability for its use. Nothing you type is sent to our servers.
How to use this builder
- 1Answer in your own words, not in OSHA's. The six headings are fixed; the content underneath is yours. A plan that reads like the regulation quoted back at itself tells an employee nothing at 2 a.m.
- 2Write the address the way you would say it to a dispatcher. Building, gate, cross street. It goes at the top of the printed plan for a reason.
- 3Name people by job title where you can. 1910.38(c)(6) allows a name or a job title, and a title survives the person leaving.
- 4Watch the coverage line on step 4. It tells you which of the six minimum elements are still blank. Six out of six is the minimum, not the target.
- 5Walk it before you file it. Take the printed plan and follow one of your own exit route assignments to the assembly point. Most plans fail on a door that is locked, a route that crosses the fire, or an assembly point in the smoke.
What OSHA requires
29 CFR 1910.38(a) says an employer must have an emergency action plan whenever an OSHA standard in part 1910 requires one. 1910.38(b) then says it must be in writing, kept in the workplace, and available to employees for review — except that an employer with 10 or fewer employees may communicate the plan orally. Construction says the same at 1926.35(e)(3).
| ¶ | The plan must include | Construction |
|---|---|---|
| (c)(1) | Procedures for reporting a fire or other emergency | 1926.35(b)(5) |
| (c)(2) | Procedures for emergency evacuation, including type of evacuation and exit route assignments | 1926.35(b)(1) and (d) |
| (c)(3) | Procedures to be followed by employees who remain to operate critical plant operations before they evacuate | 1926.35(b)(2) |
| (c)(4) | Procedures to account for all employees after evacuation | 1926.35(b)(3) |
| (c)(5) | Procedures to be followed by employees performing rescue or medical duties | 1926.35(b)(4) |
| (c)(6) | The name or job title of every employee who may be contacted by employees who need more information about the plan or an explanation of their duties under it | 1926.35(b)(6) |
Three more paragraphs travel with them. 1910.38(d) requires an employee alarm system that uses a distinctive signal for each purpose and complies with 1910.165 — construction points to 1926.159 instead, and 1926.150(e) adds that the alarm code and reporting instructions are conspicuously posted at phones and employee entrances. 1910.38(e) requires the employer to designate and train enough employees to assist in a safe and orderly evacuation. 1910.38(f) requires the plan to be reviewed with each covered employee when the plan is developed or the employee is assigned initially to a job, when that employee's responsibilities under the plan change, and when the plan is changed.
An emergency action plan is not a fire prevention plan
They are two documents. 1910.39(c) requires a fire prevention plan to list all major fire hazards with their handling and storage procedures, potential ignition sources and their control, and the fire protection equipment for each hazard; procedures to control accumulations of flammable and combustible waste; procedures for regular maintenance of safeguards on heat-producing equipment; and the names or job titles of the employees responsible for ignition sources and for fuel source hazards. Where you rely on the exemption in 1910.157(b)(1), you need both.
Fight or flee — the decision that shapes the plan
OSHA's evacuation eTool sets out four options and what each one costs you:
| Option | What it requires |
|---|---|
| Total evacuation on the alarm; nobody uses extinguishers | An emergency action plan and a fire prevention plan, employees trained accordingly, and no extinguishers in the workplace — 1910.157(b)(1) |
| Designated employees only | An emergency action plan, all general extinguisher requirements, and annual training for the designated employees; the units are still inspected, tested and maintained — 1910.157(b)(2) |
| All employees are authorized | The same, with annual training for everyone — 1910.157(b)(2), (g) |
| Extinguishers present but not intended for employee use | An emergency action plan and a fire prevention plan; the units still have to be inspected, maintained and tested — 1910.157(a) |
Whichever line you are on, the extinguishers on the wall stay on their own clocks: monthly inspection, annual maintenance and hydrostatic testing. The fire extinguisher monthly inspection log is the sheet for that.
This generator produces a template. The procedures in it are yours, not ours: it supplies no model evacuation route, no default assembly point and no head-count rule. It does not by itself establish compliance with 1910.38, 1926.35, 1910.39, the local fire code or your insurer's requirements, and it is not a substitute for the training required by 1910.38(e) or the review required by 1910.38(f).
Frequently asked questions
Sources & references
- 29 CFR 1910.38 — Emergency action plans: written plan (b), the six minimum elements (c), alarm system (d), training (e) and review (f)
- 29 CFR 1926.35 — Employee emergency action plans (construction): elements (b), alarm system per 1926.159 (c), types of evacuation (d), training and review (e)
- 29 CFR 1910.39 — Fire prevention plans: the five minimum elements of the separate document an emergency action plan does not replace
- OSHA — Evacuation Plans and Procedures eTool: emergency action plan minimum requirements, element by element
- OSHA — Evacuation Plans and Procedures eTool: Fight or Flee? The four options for portable fire extinguishers in an emergency action plan and what each one requires
Content checked against these sources — last reviewed August 28, 2026.